Electronical Disconnect Requirements
Make Amusement Ride Permit Payments Online
(Follow on-screen instructions. A minimal convenience fee is applied based on method of payment. You may cancel prior to payment authorization.)
The following section of the National Electrical Code (525.21A) is cited relating to an electrical disconnect.
525.21 Rides, Tents and Concessions.
(A) Disconnecting Means Each ride and concession shall be provided with a fused disconnect switch or circuit breaker located within sight and within 1.8 m (6 ft) of the operator’s station. The disconnecting means shall be readily accessible to the operator, including when the ride is in operation. Where accessible to unqualified persons, the enclosure for the switch or circuit breaker shall be of the lockable type. A shunt trip device that opens the fused disconnect or circuit breaker when a switch located in the ride operator’s console is closed shall be a permissible method of opening the circuit.
Contact (573) 751-2930 for further information or questions.